Overview​

This version of the CCD47 family of CCD sensors has full-frame architecture. Extremely low noise amplifiers make this device well suited to the most demanding scientific applications. To improve the sensitivity further, the CCD is manufactured without anti-blooming structures.

The device has a single serial output register. Separate charge detection circuits are incorporated at each end of the register, which is split so that a line of charge can be transferred to either output, or split between the two. The register is provided with a drain and control gate along the outer edge of the channel for charge dump purposes.

In common with all Teledyne Space Imaging CCD Sensors, the CCD47-10 is also available with a fibre-optic window or taper, or with a phosphor coating.

Key Features​​

  • 1024 by 1024 nominal (1056 by 1027 Usable Pixels)
  • Image area 13.3 x 13.3mm
  • Full-frame operation
  • 13µm square pixels
  • Symmetrical anti-static gate protection
  • Very low noise output amplifiers
  • Gated dump drain on output register
  • 100% active area
  • New compact footprint package​

​Typical Applications

  • Spectroscopy
  • Scientific Imaging
  • Star Tracking
  • Medical Imaging